Bioline Malaria Ag P.f/Pv
Product Brochure
Number of Reactions(Preps)/Kit | 25T |
Brand | ABBOTT |
Time To Result | 15 Min |
Result Time (Rapid Kits) | 15 min |
Sample Type | Blood |
Shelf Life | 24 months |
The SD BIOLINE Malaria Ag P.f/Pv test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium vivax in human whole blood.
Specomen: Whole blood
Time to result: 15 -30 minutes
Storage: 1-40 degree C for 24 months
Performance: Sensitivity: Pf-99.7%, Pv-95.5%
Specificity: 99.5 %
Optimal screening test for Plasmodium falciparum and Plasmodium vivax
Ordering Information
Cat No. Description Type Pack size
05FK80I40 SD Malaria Device 40 Tests
Bioline Malaria Ag P.f / Pan
Product Brochure
Brand | ABBOTT |
Usage/Application | Hospital |
Results | 30 min |
Test Type | Rapid Test |
shelf life | 24 months |
Cat. No | 05FK63I01 |
The Alere SD BIOLINE Malaria Ag P.f/Pan test is a rapid, qualitative and differential test for the detection of histidine-rich protein II (HRP-II) antigen of Plasmodium falciparum and common Plasmodium lactate dehydrogenase (pLDH) of Plasmodium species in human whole blood.
Optimal screening test for P.falciparum and other Plasmodium species
Ordering Information
Cat No. Description Type Pack size
05FK63I01 SD Malaria Device 1 Test
Bioline H.Pylori Ab Rapid Test
Product Brochure
Brand | SD |
Country of Origin | Made in India |
Specimen | Serum |
Shelf Life | 24 Months |
Temperature Storage | 30 Degree Celsius |
Sensitivity | 97.6% |
Specificity | 98.0% |
H.Pylori
Helicobacter pylori (H.pylori) is a spiral shaped bacterium and is found in the gastric mucous layer or adherent to epithelial lining of the stomach. H.pylori causes more than 90% of duodenal ulcers and up to 80% of gastric ulcers. Approximately two thirds of the world's population is infected with H.pylori. The immuno- chronomatographic techinques for the detection of antibodies specific to H.pylori has substantially resolved these problems.
General Information:
SD BIOLINE H.pylori test is a rapid test for the qualitative detection of antibodies of all isotypes (IgG, IgM, IgA etc) specific to Helicobacter pylori in human serum plasma or whole blood.
- Detection of all isotype (IgG, IgM, IgA) antibodies against H.pylori
- High Accuracy Sensitivity: 95.9%, Specificity: 89.6%
- Specimen: Serum. Plasma, Whole blood
Material provided with this kit are as follows:
- SD BIOLINE H.pylori test device multi-device
- Assay diluent
Bioline HIV 1/2 3.0
Product Brochure
Number of Reactions(Preps)/Kit | 30T |
Brand | ABBOTT |
ICMR Approved | Yes |
Result Time (Rapid Kits) | 20Min |
Self Time | 24 months |
Cat. No | 03FK10CE |
one step rapid immunochromatrographic test for the detection of anti - hiv 1/2 in human serum, plasma or whole blood
Determine HIV-1/2
Product Brochure
Number of Reactions(Preps)/Kit | 100T |
Brand | Abbott |
Usage/Application | Hospital |
Result Time (Rapid Kits) | 30 Min |
Sample Type | Blood |
CAT No : | 7D2343 |
A rapid in vitro qualitative immunoassay for detection of antibodies to the Human Immunodeficiency Virus Type 1 (HIV-1) and Type 2 (HIV-2)
Clear, dependable results in 15 minutes
Requires minimal training and no equipment
So easy it can be used at the lowest levels of health care service
Can use whole blood or serum/plasma
Collection can be by fingerstick or venipuncture
No refrigeration required
Storage conditions 2-30°C
Bioline Rotavirus
Number of Reactions(Preps)/Kit | 20T |
Brand | Abbott |
Result Time (Rapid Kits) | 10 -20 min |
Sample Material | Fecal |
Cat. No | 14FK10 |
• Early detection of rotavirus antigen group A all serotype
Shelf life and storage temperature: 18 months from the date of manufacturing at1-30 °C• Performance: Sensitivity : 94 %, Specificity 98.3 % (vs. RT-PCR)
Bioline Dengue Duo
Product Brochure
Number of Reactions(Preps)/Kit | 10 |
Brand | SD Bioline |
Result Time (Rapid Kits) | 15 mins |
Results | 15 - 20 min |
Cat. No | 11FK45 |
SD BIOLINE Dengue Duo
(Dengue NS1 Ag + IgG/IgM)
The SD BIOLINE Dengue Duo kit is a rapid, an in-vitro immunochromatographic, one step assay designed to detect both dengue virus NS1 antigen and antibodies to Dengue virus (Dengue IgG/IgM) in human serum, plasma or whole blood. SD BIOLINE Dengue Duo rapid test contains two test devices (left side ; Dengue NS1 Ag test, right side ; Dengue IgG/IgM test). The SD BIOLINE Dengue Duo kit is intended only for an initial screening test and reactive samples should be confirmed by a supplemental assay such as RT-PCR, IgM / IgG ELISA or HI (Hemagglutination inhibition) test.
Detect Dengue Ag and Ab simultaneously at once.
Cover acute to convalescence stage
Performance: Sensitivity : 92.4% (Dengue NS1 Ag), 94.2% (Dengue IgG/IgM)
Specificity : 98.4%(Dengue NS1 Ag), 96.4% (Dengue IgG/IgM)
In primary infection with the dengue virus, IgG antibody appears a few days after IgM. In primary infections, IgG antibodies are produced at a lower level compared to IgM but will persist for many years after infection. In secondary infections, IgG response may rise quickly before or simultaneously with an IgM response and will become the predominant immunoglobulin isotype in secondary infections.
Ordering Information
Cat No. Description Type Pack size
11FK45 SD Bioline Combo Device 10 Tests
Dengue Duo
(Dengue NS1 Ag+Ab Combo)
Bioline HCV
Product Brochure
Number of Reactions(Preps)/Kit | 30T |
Brand | ABBOTT |
Usage/Application | Hospital |
Result Time (Rapid Kits) | 15 mins |
Cat. No | 02FK10I30 |
SD BIOLINE HCV test is an immunochromatographic rapid visual test for the qualitative detection of antibodies specific to HCV in human serum, plasma or whole blood
Immobilized material: Recombinant HCV Core, NS3, NS4, NS5 AgSpecimen Type: Serum, Plasma, Whole blood
Sample Volume: 10MuL
Shelf Life: 24months
Storage: 2-30oC
Performance: Sensitivity: 99.5% and Specificity: 98%
One Step Hepatitis C Virus Test
Ordering Information
Cat No. Description Type Pack size
02FK10I30 SD HCV Device 30 Tests
BinaxNOW LEGIONELLA URINARY ANTIGEN CARD
Number of Reactions(Preps)/Kit | 22T |
Brand | Abbott |
Result Time (Rapid Kits) | 15 Min |
Cat. No | 852-000 |
Sample Type: Urine
Time to Result: 15 minutes
Kit Size: 22 tests
Performance Data: Sensitivity/Specificity: 95%/95%
Bioline DENGUE NS1 Ag
Number of Reactions(Preps)/Kit | 25 T |
Brand | Abbott |
Result Time (Rapid Kits) | 15-20 Min |
Cat. No | 11FK50 |
Bioline Dengue NS1 Ag rapid test is an in vitro immunochromatographic assay designed to detect Dengue virus NS1 antigen in human serum, plasma or whole blood.
- Diagnosis of early acute dengue infection by detecting dengue NS1 antigen
- Dengue NS1 antigen can be detected from 1 day after onset of fever
- Specimen : Serum, plasma or whole blood (100μl)
- Test result : 15~20 minutes
Determine Combo 4th Generation Test Kit For Clinical
Product Brochure
Number of Reactions(Preps)/Kit | 100 |
Brand | Alere |
Usage/Application | Hospital |
Result Time (Rapid Kits) | 15 mins |
Pack Size : 100 Test
Brand : 100 Test
Binaxnow Streptococcus Pneumoniae
Number of Reactions(Preps)/Kit | 22 Test |
Brand | Abbott |
Usage/Application | Hospital |
Cat. No | 710-000 |
Abbott BinaxNOW® S. pneumoniae Antigen Card provides accurate, rapid identification of S. pneumoniae antigen in patients with pneumococcal pneumonia and pneumococcal meningitis with an easy-to-use technology, aiding physicians in providing rapid, focused therapy.
Time to Result: 15 minutes
Performance data:
Urine Sensitivity/Specificity —86% / 94%
CSF Sensitivity/Specificity —97% / 99%
Ordering Information
Cat No. Description Specimen Pack size
710000 Streptococcus Urine, CSF 22 Tests
Pneumoniae Ag card
ACON hCG (Urine)
Brand | ACON |
Size | 50 Test |
Product Description :
Acon Pregnancy Test Strip (HCG) is a one step pregnancy test kit containing test strip. The urine sample is to be collected in a clean, dry container and almost half test strip should be dropped inside the container. The first urine sample of the day is preferred. The pack insert should be thoroughly read before use. To know how to use and read test results. Acon pregnancy test strip detects pregnancy in just 5 minutes.
Features & Specifications :
- One Step Pregnancy Test Strip
- Easy to Use
- Quick Result in just 5 minutes
- Pack of 3 Test Strips
- For more info, please refer the product pack for usage instructions
ABON hCG One Step Pregnancy Tests - For Professional Use
Product Brochure
Brand | Abon |
No of test per kit | 100 |
Roche Cardiac Trop T Sensitive Test Kit
Product Brochure
Brand | Roche |
Result Time (Rapid Kits) | 15 min |
CAT No : | 11621947196 |
Qualitative detection of troponin in anticoagulated
(EDTA or heparin) venous whole blood
• Reaction time: 15 min.
• Positive result from a threshold (cut-off) of 100 ng/L
• Storage at 2 to 8° C
• Test can be used immediately after removal from the
refrigerator
• Storage for 4 weeks at room temperature (15 to 25° C)
• Roche TROP T® sensitive rapid assay is available in 5
and 10 pack sizes
Content:
• 5 disposable test strips (individually sealed)
• 5 pipettes (150 μL)
• disposable labels
• 1 package insert
Determine HBsAg
Number of Reactions(Preps)/Kit | 100 |
Brand | Abbott |
Usage/Application | Hospital |
By detecting early markers of Hepatitis B infection, the Alere Determine™ HBsAg helps to diagnose acute infection and confirm chronic infection - allowing healthcare professionals to initiate prompt and appropriate follow-up action for infected patients.
Rapid in-vitro qualitative ICT for detection of HBsAg
Sample Type: Serum/Plasma/Whole Blood
Sample Volume: 50µL
Early marker of infection- helps in diagnosis
Facilitates appropriate follow-up of infected patients
Collection can be done by fingerprick or venipuncture
Clear, dependable results in 15 minutes
Quick Reference Card for the detection of HBsAg in
human serum/plasma or whole blood
Ordering Information
Cat No. Description Type Pack size
7D2543 Alere Determine HBsAg Strip 100 Tests
ABON Syphilis Ultra Rapid Tests (Whole Blood/ Serum/ Plasma)
Product Brochure
Number of Reactions(Preps)/Kit | 40 |
Brand | Abon |
Result Time (Rapid Kits) | 15 mins |
Bioline TB Ag MPT64
Product Brochure
Number of Reactions(Preps)/Kit | 25T |
Brand | ABBOTT |
Usage/Application | Hospital |
Results | 15 min |
Sample type | Blood |
Cat. No | 08FK50 |
SD BIOLINE TB Ag MPT64 Rapid is a rapid immune chromatographic identification test for the M. tuberculosis complex. M. tuberculosis has been known to secrete more than 33 different proteins. One of the predominant proteins, MPT64 was found in the culture fluid of only strains of the M. tuberculosis complex.
Rapid discrimination between the M. tuberculosis complex and MOTT bacilli
Identification of the M. tuberculosis complex in combination with culture systems
Sample: Colony, Condensation fluid(Solid cultures) or Liquid cultures
Interpretation time: 15minutes
Detection limit: 105CFU/ml
Ordering Information
Cat No. Description Type Pack size
08FK50 SD TB Ag MPT64 Device 25 Test