- Home
- ยป
- Our Product Range
- »
- Medical POCT
Medical POCT
Pima CD4 Analyzer
Product Brochure
Operation Mode | Fully Automatic |
Number Of Chambers | 2 |
Sample Mode | Capillary, Whole Blood |
Test Time | 20 Min |
Power | AC or Battery |
Cat. No | 260300003 |
S.No | Pima™ CD4 Cartridge | Code |
1 | Pima™ CD4 Cartridge (Qty 100) | 260100100 (Worldwide) |
2 | Pima™ CD4 Cartridge (Qty 25) | 260100025 (Worldwide) |
The enumeration of absolute numbers of T-helper cells (commonly referred to as a CD4 count) has become an essential part of monitoring the course of immunosuppression caused by the Human Immunodeficiency Virus (HIV) and the initiation of Anti-Retroviral Therapy.
The Pima™ CD4 test gives you the ability to monitor patients while they are still in your care. Consisting of the Pima™ Analyser and Pima™ CD4 Cartridge, the Pima™ CD4 test enables CD4 T-cell analysis at the point-of-care from a fingerstick or venous whole-blood sample in only 20 minutes, providing an effective and affordable tool in the management of HIV patients, specifically designed to serve the needs of the healthcare professional in the field, the laboratory or the office.
Hemocue Hb 201 System
Product Brochure
Brand | HemoCue |
Model Name/Number | Hb 201 System |
Sample Mode | Whole Blood |
Sample Volume | 10 Microlitter |
Measuring Time | Within 60 Sec |
Dimension | 160x43x85 mm |
Healthcare providers around the world rely on the immediate results so they can make the right decisions when they need them most — right at the point of care.
Have confidence in your answers at the point of care- Precise factory calibration against the ICSH reference method
- Patented microcuvette technology with excellent lot-to-lot reproducibility
- Date and time storage for up to 600 results
- Blood-based liquid controls available
Get easy access to lab-quality accuracy
- Capillary, venous or arterial whole blood sample
- Brief training with virtually no maintenance
- Link result with patient ID for medical record integration
- Printer interface
HemoCue Plasma/Low Hb System
Product Brochure
Brand | HemoCue |
Sample Mode | Plasma, serum and aqueous solution |
Display | Digital |
Sample Volume | 20 Microlitter |
Power | AC Adapter or 4 AA batteries |
Dimension | 160x210x90 mm |
The degree of hemolysis is an essential indicator of the quality and integrity of blood products. The HemoCue® Plasma/Low Hb System consists of a specially designed photometer and microcuvette for the quantitative determination of low levels of hemoglobin in plasma or serum specimens, aqueous solutions, or stored or banked erythrocytes.
Incorrect storage and insufficient deglycerolization of banked erythrocyte suspensions are typical situations where hemolysis of red cells can occur. In the laboratory, hemolysis is an important preanalytical factor that affects the accuracy and clinical utility of many test results. By assessing the degree of hemolysis before analysis, the sample can be accepted or rejected. Hemolysis is also a prime consideration in the context of perioperative or postoperative blood salvage where blood is processed by hemofiltration or by cell savers.
The HemoCue® Plasma/Low Hb System makes it possible to easily and accurately estimate hemolysis directly at the point of care. You can count on HemoCue for the right solutions for all your needs.
Have confidence in your answers at the point of care- Replace subjective visual judgement
- Precise factory calibration against the ICSH reference method
- Patented microcuvette technology with excellent lot-to-lot reproducibility
- Blood-based liquid controls available
Get easy access to lab-quality accuracy
- Plasma, serum, aqueous solutions or stored erythrocyte suspensions
- Simple to use, providing results within one minute
- Portability enables testing anywhere
- Brief training with virtually no maintenance
HemoCue WBC DIFF System
Product Brochure
Brand | HemoCue |
Display | Digital |
Measuring Principle | Imaging system characterizing white cells that are stained, identified and counted |
Dimensions | 188x157x155 mm |
Power Supply | AC adapter or batteries |
Cat. No | 123521 |
In just three minutes, you have results with the same precision and accuracy as those from a central laboratory. This will assist the physician in evaluating a patient’s condition, while the patient is still in the office.
Fitting seamlessly into a variety of clinical applications and even remote field clinics, the benefits are clear. Immediate WBC counts can mean the difference between waiting and taking action at the point of care — helping you move from assessment to treatment within minutes rather than hours or days.
Answers right when you need them- Lab-accurate results in minutes
- Faster treatment decisions and streamlined workflow
- Easy to use by non-laboratory personnel after a brief training
- Capillary or venous samples
Accuracy for confident decisions
- Factory calibration with no further calibration needed
- Unique software for internal QC
- Blood-based liquid controls available
Arkray PocketChem A1C HbA1c - Device
Product Brochure
Brand | arkray |
Model Name/Number | A1c |
Sample Mode | Whole Blood |
Measuring Principle | Boronate affinity |
Power Supply | AC100 V-240 V +-10 % 50/60 Hz |
Weight | Instrument: 0.7 kg Printer: 0.5 kg |
Dimensions (W x D x H) | W 205 x D 135 x H95 mm |
Detection method | Fluorescence quenching |
PocketChem A1c is fast, accurate and simple glycohemoglobin analyzer with ergonomoic design.
Easy calibration
Use of barcode reader to scan calibration data, patient and operator ID.
Efficient data handling
User selectable dual reporting of result. User can select from % NGSP, IFCC mmol/mol,
eAG mg/dl or eAG mmol/l
Minute samples
Just 4 µl blood required from finger prick or venous sample. The innovative blood collector makes the blood sampling easy and consistent.
Compact and lightweight
Together with user friendly basic functions and ergonomic design, PocketChem A1c becomes the ideal choice for small/medium sized hospitals and clinics.
It is lightweight (0.7kg) with footprint only the size of A5 paper. Large tables are no longer needed.
Convenient Barcode
Barcode is available with the instrument.
Prompt and automatic
By closing the lid after applying the sample, the measurement starts automatically. The result is displayed in just four minutes.
Highly reliable
Boronate affinity methodology is widely recognized as interference-free from Hb varients.
Samples | Whole blood (capillary and venous blood) |
---|---|
Measured items | HbA1c |
Measurement principle | Boronate affinity |
Detection method | Fluorescence quenching |
Measurement range | NGSP : 4-15 ??? |
Throughput | 4 minutes per sample |
Sample volume | 4 μL(whole blood) |
Imprecision | CV < 3 % at 7 % A1c (NGSP) |
Measurement conditions | 18-30 ???, 20-80 ??? relative humidity |
Memory capacity | 7000 test results |
Printer | Thermal printer, 58mm thermal paper (Optional) |
External output | USB Port |
Power supply | AC100 V-240 V ±10 % 50/60 Hz |
External dimensions | W 205 x D 135 x H95 mm |
Weight | Instrument: 0.7 kg Printer: 0.5 kg |
Warm up time | 5-20 mins dependent upon external temp conditions |
HemoCue HbA1c 501 System
Product Brochure
Measuring Time | In 5 minutes |
Model No | HbA1c 501 |
Sample Volume | 4 Micro L |
Dimensions (W x D x H) | 198 x 217 x 136 mm |
Power | 9 V DC / 1.5 A |
Cat. No | 405212 |
Stop sending samples to labs and waiting for results
Having to send blood samples to the lab and wait for the results to come back can be very frustrating. Not only is it time-consuming, it also delays the treatment of the diabetes patients. As a medical professional, you should be able to carry out tests fast and easy at the point of care, and provide your patients with reliable result straight away.
An automated system for testing HbA1c
HemoCue® HbA1c 501 System is a fully automated point-of-care system for testing HbA1c. Hemoglobin A1c (HbA1c) is a glycated form of Hb that is tested primarily to identify the average amount of glucose (sugar) present in patients’ blood over the past three months. Blood sugar testing is an important part of the diabetes care and necessary for millions of diabetics.
Advantages of using our point-of-care system
Our HemoCue® HbA1c 501 System brings many advantages into your work process. It provides a safe workflow for excellent patient care. Every step of the test is simplified to minimize human errors. Every element from size to the storing and handling of test cartridges is designed to be ideally suited for how you work. The system is easy to use, the tests are carried out quickly, and the results are exceptionally reliable. With our system, you will never have to doubt an answer at the point of care.
Onscreen instructions simplify every step of the process
Testing HbA1c with our system includes only a few simple steps. But to make it as easy as possible for you to carry out the tests, we provide you with clear online instructions animated on the screen. They describe exactly how you should do so that you never have to feel insecure about performing the tests.
Certified according to IFCC and NGSP to ensure quality
The HemoCue® HbA1c 501 system is certified according to the International Federation of Clinical Chemistry & Laboratory Medicine (IFCC) and the National Glycohemoglobin Standardization Program (NGSP). It ensures that our system has a measuring range of 20-130 mmol/mol (IFCC) or 4.0-14.0% (NGSP) to ensure the quality of the tests.
Get the right answers at the right time every time
In the end, the result of the test is what decides the treatment of your patient. The test must not vary from time-to-time, on the contrary, it needs to be accurate every single time.
HemoCue Hb 301 System
Product Brochure
Brand | HemoCue |
Model Name/Number | Hb 301 System |
Sample Mode | Whole Blood |
Measuring Principle | 3 Sec |
Power Supply | AC adapter or 4 AA batteries |
Optimized for anemia screening in primary care and blood donation settings, the HemoCue Hb 301 System is a simple and convenient solution. The HemoCue Hb 301 System provides quick, easy access to lab-quality results without compromising accuracy, even in demanding climates with high temperatures and humidity.
Have confidence in your answers at the point of care- Precise factory calibration against the ICSH reference method
- Patented microcuvette technology with excellent lot-to-lot reproducibility
- Robust testing within a wide range of temperatures and humidity
- Blood-based liquid controls available
- Capillary, venous or arterial whole blood sample
- Brief training with virtually no maintenance
- Link result with patient ID for medical record integration
- Printer interface
Hemocue Hb 201 Microcuvettes
Number Of Chambers | 4 |
Brand | HemoCue |
Storage | 15 - 30 c |
Size | 4 x 50 microcuvettes |
Cat. No : | 111716 |
the HemoCue®Hb 201+ System has become a standard in Hb point-of-care testing. Healthcare providers around the world rely on the immediate results so they can make the right decisions when they need them most — right at the point of care.
Microcuvettes for collection and measurement of blood samples on the HemoCue® Hb 201+ System and HemoCue® Hb 201 DM System. These microcuvettes come in bottles (vials/cylinders) with 50 in each bottle (4x50).
Hemocue HbA1c 501 Test Cartridge
Brand | Hemocue |
Sample Type | Blood |
Size | 10 |
Storage | Room temp |
Cat No : | 405116 |
HemoCue® HbA1c 501 System is a fully automated point of care system where every element – from its size to the storing and handling of cartridges – is thought through to be ideally suited for how you work.Tested according to HemoCue principles, and with automatic checks and calibrations built into the system, you can count on getting the right answer at the right time – at the point of care. So you won’t miss a beat in caring for your patients.
The test cartridges are stable at room temperature for their entire shelf life. Cartridges come in packs of 10, individually wrapped.
Hemocue Hb 301 Microcuvettes 200 T
Brand | HemoCue |
Storage | 10 to 40 C |
Cat. No | 111803 |
Pack Size | 4 x 50 |
Specimen | blood |
Optimized for anemia screening in primary care and blood donation settings, the HemoCue Hb 301 System is a simple and convenient solution. The HemoCue Hb 301 System provides quick, easy access to lab-quality results without compromising accuracy, even in demanding climates with high temperatures and humidity.
Have confidence in your answers at the point of care- Precise factory calibration against the ICSH reference method
- Patented microcuvette technology with excellent lot-to-lot reproducibility
- Robust testing within a wide range of temperatures and humidity
- Blood-based liquid controls available
- Capillary, venous or arterial whole blood sample
- Brief training with virtually no maintenance
- Link result with patient ID for medical record integration
- Printer interface
Afinion 2 Rapid Multi Assay Analyzer
Product Brochure
Instrument Name | Biochemistry Analyzer |
Brand | Abbott |
Usage/Application | Hospital |
Automation | Semi Automatic |
Assays | Cardiac, Diabetes, Thyroid |
Cat. No | 1116681 |
Weight | 3.4 Kg |
Brand | Abbott |
Size | 20 cm x 19 cm x 33 cm |
Display | Color Touch Display |
Connectivity | Connectivity Solutions That Support Poct1-A |
Maintenance | No Maintenance Needed |
S.No | Code | Pima CD4 Cartridge |
1 | 1116795 | Afinion 2 Test Kit - Hb1Ac |
2 | 1116787 | Afinion 2 Test Kit - CRP |
3 | 1116781 | Afinion 2 Test Kit - ACR |
4 | 1116801 | Afinion 2 Test Kit - Lipid Panel |
Improve the way you diagnose, monitor and manage your patients
The Afinion 2 Analyzer is a compact, rapid, multi-assay analyzer that provides valuable near patient testing at the point-of-care.
With the Afinion System theres no need to send patients to the lab or spend time tracking down their results. That way you can keep your focus where it belongs on the patient.
Mission-Hemoglobin test strip
Product Brochure
Model Name/Number | Mission Hb Hemoglobin Test strips |
Usage/Application | Lab, Clinical and Hospitals |
Number Of Strips | 2 x 25 T |
Cat No | C131-3021 |
Expiry | 2 year |
• Hemoglobin (Hb) and Hematocrit (Hct) results in < 15 seconds
• Simply insert strip, apply specimen and read results
• Low maintenance and quick clean up
• Precise results equivalent to automatic hematology analyzers
• Wide Hb mesurement range of 4.0-25.6 g/gL with Hct range of 13-75%
• Excellent precision in both low and hign Hb concentration
Mission Hb Hemoglobin Testing System
Product Brochure
Brand | Acon |
Result Time (Rapid Kits) | 15 seconds |
Memory | Stores up to 1,000 result |
Data Transfer | via Mini USB port |
Cat No | C111-3021 |
Designed for POC Testing
- Portable handheld
- Large, easy-to-read LCD
- Stores up to 1,000 results
Accurate
- Precise results equivalent to laboratory analyzers
- Wide Hb measurement range of 4.5 – 25.6 g/dL
- Calculated Hct range of 13 – 75%
Quick & Convenient
- Results in < 15 seconds
- Auto-calibration
- Fast data transfer via Mini USB port
Acon Mission Urinalysis Strips - 10P, 14P & GP
Product Brochure
Brand | Mission |
Sample Types | Urine |
Pack Size | 100T |
CAT No | U031-101, U031-141, U031-021 |
Product Class | Cartridges |
CoaguChek XS System
Product Brochure
Brand | Roche |
Sample Type | Non Anti-Coagulated Venous Whole Blood |
Test Type | Anti-Coagulation |
CAT No | 04837975001 |
Product Class | Coagulation Meter |
CoaguChek XS PT Test Strips (24T)
Product Brochure
Brand | Roche |
Product Class | Coagulation Test Strips |
Sample Type. | Non Anti-Coagulated Venous Whole Blood |
Pack Size | 24T |
CAT No | 04625358172 |
HemoCue WBC DIFF Microcuvettes
Instrument Name | Microcuvettes |
Brand | HemoCue |
Number Of Parameters | neutrophils, lymphocytes, monocytes, eosinophils and basophils |
Cat. No | 113505 |
Size | 2 x 25 Microcuvettes |
the HemoCue®WBC DIFF System makes it possible to get not only lab-accurate white blood cell counts but also five-part differentials at the point of care. In just five minutes, you have accurate counts for neutrophils, lymphocytes, monocytes, eosinophils and basophils.
Fitting seamlessly into a variety of clinical applications and even remote field clinics, the benefits are clear. Immediate WBC DIFF counts can mean the difference between waiting and taking action at the point of care — helping you move from assessment to treatment within minutes rather than hours or days.
Microcuvettes come packaged individually wrapped pack of 50 (2x25)
Arkray PocketChem UA PU-4010
Product Brochure
Brand | arkray |
Display | Digital |
Dimensions | 124x81x36 mm |
Memory | 100 Tests |
Method | Dual wavelength reflectance method |
Cat. No | PU-4010 |
Reaction Time | 1 min/test |
PocketChem UA PU-4010
Palm-sized, fitting easily into a doctor's bag or uniform pocket.
In order to achieve the goals of "anytime", "anywhere" and "easy to handle", the printer can be separated from the "PocketChem" analyzer, leaving it with a weight of just 180g.
- Multiple functions
- Palm-sized meter driven by two batteries
- Easy operation and daily maintenance
- Highly reliable test results with Creatinine compensation
Siemens Multistix 10 SG Reagent Urine Analysis Strip
Product Brochure
Brand | Siemens |
Number of Reactions(Preps)/Kit | 100 |
Cat. No | 2300 |
Abbott Nycocard Reader II
Product Brochure
Brand | Abbott |
Weight | 540g (incl. Reader pen and batteries) |
Display Type | LCD, 2 x 16 Characters |
Reader Pen | L:144 MM, D; 29.5 MM |
Batteries | Rechargeble Nimh Batteries Only, Size AA, 1.2 V, Recharge 8 - 18 Hours |
S.No | Code | Cartridge |
1 | 1116083 | Nycocard™ HbA1c (24T) |
The NycoCard READER II is a small battery powered instrument, designed to measure all NycoCard products. It consists of two units: the instrument box, which is the operational and calculating unit, and the Reader pen, which detects the signal.
Skyla HB1 POC Clinical Chemistry Auto Analyzer
Product Brochure
Brand | Skyla |
Instrument | Clinical Chemistry Analyzer |
Model No. | D-66386 |
The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample.
HemoCue Cleaner
Product Brochure
Brand Name | HemoCue |
Appilcation | Cleans the optical lens of analyzer |
Pack Size | 5 nos/ Pack |
CAT No | 765347 |
Product Class | HemoCue Acessories |
SD Urometer 120 & 720 Analyzer For Laboratory
Product Brochure
Instrument Name | Biochemistry Analyzer |
Usage/Application | Hospital |
Brand | abbott |
Type | SD Urometer 120 and 720 |
S.No | Test Strip |
1 | SD Urocolor 10 - 100T |
Urine Chemistry analyser
Based on reflectance photometer.
3.2 inch TFT color display having resolution(320*240 )
Auto calibration with power on.
Enhancing work efficiency by flexible options between quick & normal mode.
Enhancing user-convenience even for left hander by ergonomics design.
4~11 parameter testing available.
Maximum 300test/hr.
Memory- 100000 test results.
Easy to input multiple ID by key board, PC and barcode reader.
Interface: RS 232c and USB
Siemens Clinitek Microalbumin 2
Brand | SIEMENS |
CAT No; | 2083 |
Quantity | 25 Strips |
CLINITEK® Microalbumin 2 Strips provide albumin, creatinine and albumin-to-creatinine ratio results in one minute. The CLINITEK Microalbumin product is useful to test for microalbuminuria in patients with diabetes or hypertension in order to detect early kidney disease. The strips are used on the CLINITEK Status family of analysers.
Product Highlights
- Albumin, creatinine, and albumin-to-creatinine ratio results to help identify clinically relevant microalbuminuria
- Increased sensitivity of albumin as recommended by ADA guidelines: sensitivity as low as 2.0 mg/dL
- Results are corrected for varying urine concentrations when used on the CLINITEK Status urine analyzer, replacing the need for 24-hour urine collection and measurement.
Product Features
CLINITEK Microalbumin 2 Reagent Strips make it simple and easy to test patients with diabetes. Because testing for microalbuminuria can detect kidney disease in its early stages, physicians may begin intervention earlier than might otherwise have been possible. CLINITEK Microalbumin 2 Reagent Strips permit detection of elevated albumin sooner, more sensitively and more specifically than products designed for general protein testing.
Benefits
- The CLINITEK Microalbumin 2 Reagent Strips provide semi-quantitative results with a hard-copy report on the CLINITEK Status family of analysers, making them ideal for point-of-care testing. Patient’s urine sample sticks can be tested immediately during a physician, clinic or hospital visit, rather than sending them out and waiting for results.
- The urine sample test strips are also convenient for testing random samples, eliminating the need to collect a timed sample.
Mission Urinalysis Strips
variants | GP, 10 P & 14 P |
Controls | Available |
Brand : | Acon |
Size | 100 / 25 T |
Reliable Results
- Analytical sensitivity comparable to market leaders
- High quality color chart ensures accurate visual reading
Ease of Use
- Compatible for visual and analyzer reading
- Over 35 different combinations available
- 24 months shelf life for unopened canisters
- 3 months shelf life once the canister is opened
Mission Hemoglobin Hb Test Strip
Product Brochure
Brand | Mission |
Cat. No | C131-3021 |
S.No | Size | Test Strips |
1 | 50 | Mission Mission Hb Hemoglobin Strips |
System Details :
Features | Specifications |
Methodology | Reflectance Photometry |
Detection Principle | Methemoglobin |
Time to Results | < 15 seconds |
Memory | 1,000 tests with date/time and ID number |
Specimen Volume | 10 µL |
Specimen Type | Capillary and Venous whole blood |
Hb Measurement Range | 4.5-25.6 g/dL |
Hct Range | 13-75% |
Wavelengths | 525 nm |
PC Interface | Mini USB Port |
Calibration | Automatic |
Hb Within Run Precision | ≤ 3% |
Hb Total Precision CV | ≤ 3% |
Accuracy |
|
Operating Conditions | 10 – 40 ºC (50 -104 ºF); ≤90??? RH |
Meter Storage Conditions | 0-50 °C (32-122 °F); ≤90% RH |
Strip Storage Conditions | 2-30 °C (36-86 °F); ≤85% RH |
Strip Shelf Life | 2 years unopened canister; 3 months opened canister |
Power Source | 3 AAA Batteries or AC Adapter |
Battery Life | 2,700 tests or 360 hours |
Automatic Shut Off | 8 minutes |
Meter Dimensions | 127 × 58 × 25 mm (5.0″ x 2.28″ x 0.09″) |
LCD Dimensions | 39 × 37 mm (1.54″ x 1.46″) |
Abbott Afinion Hba 1 C Human Whole Blood Test Kit
Product Brochure
Brand | Abbott Afinion |
Result Time (Rapid Kits) | 15 min |
Sample Type | Blood |
Requires only | 20 ml of specimen |
Capillary tubes | 20 ml |
Country of Origin | Made in India |
Immediate point of care HbA1c results for efficient monitoring of glycemic control.
The Afinion HbA1c assay is a test for quantitative determination of glycated hemoglobin (HbA1c) in human whole blood, used to monitor metabolic control in patients with diabetes. It provides the immediate test results you need for improved diabetic control, better patient outcomes, and enhanced clinic efficiencies.
SHORT ASSAY TIME IN 3 MINUTESThe CLIA-Waived Afinion HbA1c test gives you reliable, high quality results conveniently available when and where you need them.
TIMELY TREATMENT CHANGESDiabetes can be treated and managed by healthful eating, regular physical activity, and medications to lower blood glucose levels. Lowering the HbA1c has been shown to reduce microvascular complications of diabetes and is also associated with long-term reduction in macrovascular disease.
LONG SHELF LIFE OF REAGENTSPatient consultations can be carried out with confidence. The HbA1c Test Cartridge contains all reagents necessary for the measurement of glycated hemoglobin. The test has 3 months room temperature storage.
Arkray Spotchem El Se-1520
Product Brochure
Model Name/Number | SE-1520 |
Brand | arkray |
Display | Digital |
Dimensions | 225x135x138 mm |
Sample Volume Range | 22 Microlitter |
Sample | Whole Blood, Plasma, serum and urine |
SPOTCHEM EL SE-1520
SPOTCHEM EL is an electrolyte analysis system with capacity for total electrolyte analysis requirements in all fields.
Fast, accurate and simple electrolyte analysis of body fluids-essential in an emergency.
- Whole blood, serum, plasma and urine can be measured with 22 ul
- Two types of special twin-pipettes are available.
- Easy calibration can be completed with magnetic card
- Na, K, Cl are measured at the same time on the same E-Plate
Mission U500 Urine analyzer
Product Brochure
Instrument Name | Urine Analyzer |
Brand | Mission |
Automation | Semi Automatic |
Display | Digital |
Cat No | U211-101 |
Accurate and Efficient
• Up to 500 tests/hour for medium volume labs and small hospitals
• Large LCD color touchscreen offers intuitive menu navigation
• Ability to input urine color and clarity for better record keeping
• Accuracy equivalent to market leaders
Easy to Operate
• More than 15 combinations of strips available, including Microalbumin, Creatine, Ascorbic Acid and Calcium
• Automatic strip detection and alignment
• Uniquely designed strip platform/waste tray unit for easy one-step cleaning
Accu-Chek Active Blood Glucose Meter
Model Name/Number | Active |
Usage/Application | Hospital |
Measurement Range | 50 mmol/L |
Averages | 28 days |
Result Time | 3 sec |
Display | Digital |
Sample Volume | 0.7 ul |
Country of Origin | Made in India |
CoaguChek XS PT Test Strips (48T)
Product Brochure
Brand | Roche |
Pack Size | 48T |
Product Class | Coagulation Test Strips |
Sample Type. | Non Anti-Coagulated Venous Whole Blood |
CAT No | 04625315160 |
On Call Plus Glucometre & Test Strips
Brand | ACON |
Cat. No | OCP10s |
S.No | Code | Size | Test Strips |
1 | G133-111 | 50 | On Call Plus Blood Glucose Test strips |
2 | G133-119 | 200 | On Call Plus Blood Glucose Test strips |
Designed By ACON Labs USA
For over 23 years, ACON Labs has led the way in making high-quality diagnostic and medical devices more affordable to people all around the world.
Headquartered in San Diego, California, the US office is the centre of strategic management, innovative research and development.
- Early Detection of Hypoglycaemia
- Post Surgery Sugar Monitoring
- Monitoring Blood Sugar at Home
- Monitoring Blood Sugar at Hospital
Technology conceived and designed by ACON Labs USA ensures accurate reliable blood sugar tests recommended by Doctors for patients at home and hospitals.
The On-Call Plus Technology is so sensitive only 0.4 Micro Litre of Blood Sample is required to process the blood sugar
Quick Results in 10 Seconds.
The Starter Kit has been designed for new users of Glucometer to ensure proper monitoring of blood sugar levels.
- Hospitals
- Clinics
- Home Care
- Elderly
- Pregnant Women.
Accu-Chek Active blood glucose meter
Display | 96-segment liquid crystal display (LCD) |
Battery Life | approx. 1000 tests or approx. 1 year |
Interface | USB (Micro B) |
Memory Capacity | 00 test results with time and date, as well as 7, 14, 30 and 90 days averages |
Brand | Roche |
Testing your blood glucose is an essential part of managing diabetes. The Accu-Chek Active blood glucose meter can help to make it convenient by giving you fast, hassle-free, and accurate results in simple steps.
Accu-Chek Guide Test Strips (50T)
Brand | Roche |
Sample Type | Whole Blood |
Test Type | Blood Glucose |
CAT No | Chek Guide |
Product Class | Glucose test strips |
Accu-Chek Instant Test Strips (25T)
Brand | Roche |
Sample Type | Whole Blood |
Pack Size | 25T |
CAT No | Chek Instant |
Product Class | Glucometer |
HemoCue Albumin 201 System
Product Brochure
Brand | HemoCue |
Model Name/Number | Albumin 201 system |
Display | Digital |
Sample Mode | Urine; Morning spot, overnight or 24 hr collection |
Sample Volume | 8 Microliter |
Power | AC adapter |
Dimension | 115x170x66 mm |
The HemoCue Albumin 201 System is an easy, lab-accurate means of identifying microalbuminuria – long before any possible symptoms of renal or vascular complications may appear. HemoCue’s patented microcuvette technology enables quantitative test results right at the point of care. You can make immediate treatment decisions, and give direct feedback to the patient.
Certainty in vital decisions- Lab-accurate results for screening, diagnosis and monitoring
- Ability to monitor changes in albumin concentration in the very low range (5-20 mg/L)
- Detection of low concentrations enables early treatment to delay the onset of future microvascular complications
Fast results with ease
- Ease of use with minimal training – Three simple steps
- Test results in just 90 seconds
- No need for lab confirmation due to quantitative results
Trusted and accepted methodology
- Built on HemoCue’s proven microcuvette technology
- Factory calibrated system, ensures sustainable and reliable results
HemoCue Glucose 201 RT System
Product Brochure
Brand | HemoCue |
Sample Mode | Capillary, Venous or Arterial whole blood |
Sample Volume | 4 Microlitter |
Power | Ac Adapter or AA Batteries |
Result | 1 min |
The HemoCue Glucose 201 System puts lab-equivalent answers in health professionals’ hands when they’re needed most — at the point of care. Not only does the unique cuvette technology enable accuracy in just three simple steps, but it also a workflow that reduces contamination risks.
Enables right decisions at the point of care- Used in screening, monitoring and aiding in diagnosing diabetes
- Precise monitoring for better glycemic control
- Microcuvette technology means no need to bring analyzer near patients, a workflow that reduces the risk of spreading infection
- Individually wrapped microcuvettes to minimize contamination and maximize shelf-life
- No clinically significant lot-to-lot variation
- Fixed analyzer calibration, means no need to recalibrate
- Portable and battery-operated system with room temperature microcuvette storage
Arkray Hemoglobin Testing Meter, Model Name/Number: Pocketchem Hemog
Product Brochure
Brand | arkray |
Model Name/Number | Pocketchem Hemo G |
Battery Operation | 2 X AAA 1.5V alkaline manganese batteries |
Memory | 500 Test Results |
Display | LCD |
- Compact handheld Hb testing device with calculated HCT
- Just 7µl Blood required (Venous / Whole blood)
- Special Micropipette to collect the right volume of blood sample
- Results calibrated to cell counter
- Easy 4 step process & result in just 5 seconds
POCKETCHEM HemoG meter | |
---|---|
Battery operation | 2 X AAA 1.5V alkaline manganese batteries |
Number of measurements | More than 1,000 measurements(with new batteries) |
Method of measurement | Optical method of the reflectance at 525 nm for determination of haemoglobin |
Display | LCD |
Operation buttons | 3 button (Power ON/OFF, Up and Down buttons) |
Memory | 500 test results |
POCKETCHEM HemoG Strips | |
---|---|
Measurementrange | Hb: 5 ~25 g/dL |
Repeatability of strip | 1) 5.0 ~ 10.0 g/dL : Under SD ± 0.5 g/dL 2) 10.1 ~ 25.0 g/dL : Under CV 3% |
Reference method | HiCN and Met-Hb method |
Type of sample | Fresh capillary blood for self-testing & professional Venous blood samples must be taken by a healthcare professional Venous blood sample is used EDTA or Heparin anticoagulant tube |
Blood sample volume | 7??? blood sample |
Measurement time | 5 seconds |
Storage temperature | 8~30??? |
Measurement temperature | 5~45??? (41 - 113 ???) |
Humidity: | 10- 90 %RH |
Siemens EPOC Blood Analysis System with EPOC NXS Host
Product Brochure
Instrument Name | EPOC |
Brand | Siemens |
The epoc Reader and Host2 Mobile Computer devices work together to bring you the right result at the right timeThe nearly instantaneous delivery of BGEM (blood gases, electrolytes, and metabolites) results at the bedside enables you to make immediate treatment decisions that may lead to improved patient outcomes Simply insert the Test Card into the epocReader and obtain a blood sample from the patientOnce fresh blood passes across the biosensors on the epoc Test Card, results are sent to the epoc Host2 Mobile ComputerWith the optional EDM System and LIS interface components, the test result is then wirelessly transmitted instantly over your existing Wi-Fi network to your EDM, LIS and EMR
Benefits
Auto-scans Test Card Barcode for simplified quality complianceIncorporates automated, integrated calibration and quality checks and fully portable; AC/rechargeable batteryDoes not require a committed blood sample for Test Card calibrationConnects wirelessly and integrates easily with your facility''s existing networkDelivers accurate, bedside results in about 3 minutesCritical result management with electronic documentationIntegrated 1D (2D-ready) Barcode ScannerEasy-to-use Operator/Patient/QC lockoutsCustomizable web-based epoc Host software and LIS/HIS/EMR connectionImprove documentation and results management
Specifications11 Analytes on 1 Test Card pH, pCO2, pO2, Na , K , Ca , Cl-, Glu, Hct, Lac, and CreaCalculated values cHCO3-, cTCO2, BE(ecf), BE(b), cSO2, cHgb, eGFR, eGFR-a, AGap, and AGapKRoom temperature test card storageCritical result reportingTest Card and patient ID bar codingTest with 92 L fresh whole bloodOperator / EQC lockoutsTransmit results securely in real time
Mission U120 Smart Analyzer
Product Brochure
Instrument Name | Urine Analyzer |
Usage/Application | Lab, Hospital and on site |
Brand | Mission |
Display | Digital |
Cat No : | U117 - 101 |
High Accuracy and Reliability
• Automatic calibration before each test - No calibration strips required
• Up to 120 test/hour in Continuous Mode
• Over 15 combinations available for analyzer reading
• Can read ALB/CRE strips
Easy Operation
• Saves and recalls the last 2,000 results automatically
• Robust construction
• Clear on-screen instruction
• QC Lockout function with QC tests reminders
Data Management
• Includes RS232C and USB ports for data transfer to a computer and LIS
• HL7 compliant
View More